EISF IQ

Place of use

For transmission of analogue and digital signals instrument and control systems

In dry and wet locations

Chemistry industry

Industrial signaling and process control circuit.

Petrochemistry industry

Electrical measuring devices to instrument panel

Gas stations

Control cabinets to supervisory consoles and panels

Structure

Desing Standard NF M 87-202
Conductor UTE C 32-014, DIN VDE 0295,IEC 60228 ,     
  EN 60228 Solid or stranded electrolytic copper
Insulation NF C 32-020  Pvc compound
Wrapping Pes tape
Individual screen Tinned copper drain wire(7X0,20 mm)+ Aluminium/Pes tape
Individual sheath NF C 32-020  Pvc compound
Stranding In layers of optimum pitch
Wrapping Pes tape
Overall screen Tinned copper drain wire(7X0,20 mm)+ Aluminium/Pes tape
Outer sheath NF C 32-020  Pvc compound
Outer sheath colour Light blue
Operating voltage [V] 300/500 V
Test voltage [V] core/core 2000V
Test voltage [V] core/screen 1500V
Bending radius  [mm] 8XCable Ø
Temperature range  [°C] -40°C ~+90°C during operation
   
   
Tests  
   
Flame retardant IEC 60332-1-2; VDE 0482-332-1-2; EN 60332-1-2
Flame propogation IEC 60332-3-24; VDE 0482-332-3-24; EN 60332-3-24
Oil resistant ICEA S-73-532  Test temperature +70°C, duration 4h
UV resistant UL 1581 section 1200
   

Product Code Dimension and Weights Electrical Properties
Nominal Cross Section Overall Diemeter
( ~ )
Net Weight
( ~ )
Standart Lenght Max. Dc Conductor Resistance at 20◦ C Current Carrying Capacity
In Ground at 20° C On Air at 30° C

Technical Info

  Values             
PropertiesUnit1x0,80mm (0,50mm²)7x0,40mm (0,88mm²)7x0,53mm (1,50mm²)             
               
Conductor resistance (20°C)      Ω/km  max.37,521,412,5             
Insulation resistance      MΩ/km  min.500             
Mutual capacity      nF/km  max.145160180             
              
1 serieNumber of pairs, triples or quads / 01 to 27               
2 serieLay up in pairs (IP), triple (IT), quads (IQ)               
3 serieCore section 05 (0,5mm²), 09 (0,88mm²), 15 (1,5mm²)              
4 serieIndividual screen + overall screen(EI)               
5 serieMechanical protection: without armour (SF)  

Catalog Info