CCTV AL HFFR

Place of use

These cables are used in short range video, audio and signal transmission in close circuit TV and camera systems. This type of cables is halogen-free, has flame-retarder and low smoke density.

Structure

Coax. Inner conductor

7x0,20 mmØ Stranded Annealed Copper Wire

Coax. Insulation

2,50±0,1 mmØ Foamed Polyethylene

Coax. I. and II. Screen

%100 AL-PES Tape Shielded ve Aluminium Wire Braid

Control Conductive

7x0,20 mmØ (0,22 mm²) Stranded Annealed Copper Wire

Control Insulation

HFFR Insulated Green, Yellow

Power Insulation

16x0,19 mmØ (0,50 mm²) Stranded Annealed Copper Wire

Power Insulation

HFFR, Red, Black

Overall Screen

Screening is made by combining coaxial cable and the
control cores to each other by the appropriate pitch and
then by screening this combination with Al-PES.

Outer Sheath

7,0 mmØ HFFR, RAL 7001 Grey

 


 

Product Code Dimension and Weights Electrical Properties
Nominal Cross Section Overall Diemeter
( ~ )
Net Weight
( ~ )
Standart Lenght Max. Dc Conductor Resistance at 20◦ C Current Carrying Capacity
In Ground at 20° C On Air at 30° C

Technical Info

CONDUCTOR
RESISTANCE
MUTUAL
CAPACITANCE
IMPEDANCEOPERATING VOLTAGETEST VOLTAGEBENDING 
RADIUS
TEMPERATURE 
RANGE
0.22 mm²= 79Ω/km
0.50 mm²= 39Ω/km
67 pF/m75±3Ω250 V1200 V10x D mm-30ºC+70ºC
FLAME RETARDANT 

TEST
FLAME RETARDANT 
TEST
TEST ON CORROSIVENESS 
OF COMBUSTION GASES
HALOGEN FREE 
TEST
SMOKE DENSITY 
TEST
IEC 61034-2
VDE 0482-1034-2
EN 61034-2
IEC 60332-1-2
VDE 0482-332-1-2
EN 60332-1-2
IEC 60754-2
VDE 0482-267-2-3 
EN 50267-2-3
IEC 60754-1 
VDE 0482-267-2-1 
EN 50267-2-1
IEC 60332-3-25
VDE 0482-332-3-25
EN 60332-3-25


Catalog Info